USABLE ENERGY CALCULATOR · OCTOBER 2026

Turn the watt-hours on the box into a planning estimate.

Rated battery capacity is a starting point—not a runtime promise. Enter capacity, expected system efficiency, intentional reserve, and average load to estimate usable AC energy, runtime, and the rated capacity needed for a target duration.

Use evidence when you have itThe default 85% efficiency and 10% reserve are planning assumptions, not claims about every product. Replace efficiency with exact-product discharge evidence or a controlled runtime measurement when available.

Affiliate disclosure: Power Prep Labs may eventually earn a commission from clearly labeled shopping links, at no extra cost to you. No paid links are currently active.

Calculate usable watt-hours and runtime

The calculator applies efficiency first, then keeps the selected reserve unused. The load is an average in watts; cycling appliances should use a representative measured average rather than only their running label.

Capacity shortcut
Usable planning energy1,567 Wh
Estimated runtime7.8 hours
Rated capacity needed2,092 Wh
Target energy margin−33 Wh

At these assumptions, the station falls about 0.2 estimated hours short of the 8-hour target.

Planning estimate only. Actual output can change with inverter standby consumption, load level, temperature, battery age, state of charge, shutdown thresholds, and model-specific limits.

See how the assumptions change the answer

The table holds rated capacity at your entered value and shows usable watt-hours across three efficiency assumptions and three reserve choices. It is a sensitivity check—not evidence that a specific product achieves any cell.

Efficiency0% reserve10% reserve20% reserve

The formulas

usable Wh = rated Wh × efficiency × (1 − reserve)runtime hours = usable Wh ÷ average load Wrated Wh needed = average load W × target hours ÷ efficiency ÷ (1 − reserve)

With the defaults, 2,048 rated Wh × 0.85 efficiency × 0.90 after reserve equals 1,566.72 usable planning Wh. Dividing by a 200 W average load gives about 7.8 hours.

Efficiency and reserve answer different questions

Watt-hours still do not prove compatibility

A station can contain enough energy and still be unable to start or continuously power the load. Screen continuous output and motor startup separately, then verify voltage, waveform, grounding, ports, cables, transfer behavior, environmental limits, and the exact manuals.

Add the real loads and screen current models → Compare an exact capacity with the 1 kWh and 2 kWh classes →

Primary references and related guidance