Power Prep Labs is designed to help people create a preliminary energy budget. It does not certify electrical compatibility or replace the manuals and professional guidance applicable to your equipment.
Capacity calculation
For each device, raw energy is running watts × quantity × duty cycle × hours. The calculator totals those results, then divides by the selected conversion efficiency and usable battery share:
recommended Wh = raw Wh ÷ efficiency ÷ (1 − reserve)
The default 85% system efficiency and 10% reserve are planning allowances, not claims about a particular product. Change them when reliable product-specific data is available.
Continuous output
The continuous-output minimum is the sum of running watts for devices that may operate together, multiplied by the selected output headroom:
continuous minimum = simultaneous running watts × (1 + headroom)
Combined startup requirement
A motor can start while other equipment is already running. For each load, the calculator finds its startup increment—reported startup watts minus that device’s running watts—then adds the largest increment to the simultaneous running total:
startup minimum = simultaneous running watts + largest startup increment
This assumes one device starts at a time. If multiple motors can start together, or if protection logic and waveform behavior are unknown, use a more conservative assessment and test the exact setup safely. Motor behavior, voltage, and manufacturer protection logic can still make equipment incompatible even when the numbers appear sufficient.
Representative appliance presets
Quick-add values are editable starting points. Actual consumption varies by model, age, settings, ambient conditions, duty cycle, and startup behavior. Prefer a device nameplate, manufacturer documentation, or a suitable power meter. For cycling devices, measure over a representative period.
Editorial policy
We will identify whether a value comes from a manufacturer, a calculation, or our own test. We will link important specifications to primary sources, show the last verification date, document meaningful corrections, and never describe a product as tested unless we actually tested it. Affiliate economics will not determine rankings.
Safety boundaries
- Do not backfeed a home through an outlet.
- Use a licensed electrician for transfer equipment, panel integration, hardwired loads, and situations requiring professional installation.
- Medical and life-sustaining equipment requires a backup plan approved for that equipment and situation.
- Verify voltage, continuous output, startup surge, waveform, grounding, neutral behavior, environmental rating, and connector compatibility.
- Runtime is affected by temperature, battery condition, inverter idle consumption, changing loads, and product operating modes.