Calculate the array before connecting the cable.
Enter one matched panel's electrical specifications, the planned series/parallel layout, and the power station's published solar-input limits. The tool calculates array voltage, current, and nameplate power, then identifies entered limits that require a stop.
Affiliate disclosure: Power Prep Labs may eventually earn a commission from clearly labeled shopping links, at no extra cost to you. No paid links are currently active.
Screen a matched-panel array
The defaults model two 100W-class panels in series against an 11–60V, 15A, 500W station input. Replace every value with the exact figures from the proposed panel and station documentation.
VOLTAGE: 54.6 V cold Voc ≤ 60.0 V max; 40.0 V Vmp is within 11.0–60.0 VCURRENT: 5.4 A Isc and 5.0 A Imp ≤ 15.0 A maxPOWER: 200 W nameplate ≤ 500 W station maximumThe planning ceiling is the lowest of array nameplate power, the entered station maximum power, and Vmp × entered station maximum current. It is not a charging-speed promise.
The formulas
total panels = panels in series × parallel stringsarray Voc = panel Voc × panels in series × cold-condition factorarray Vmp = panel Vmp × panels in seriesarray Isc = panel Isc × parallel stringsarray Imp = panel Imp × parallel stringsarray nameplate W = panel W × total panelsFor matched panels, series raises voltage while current stays approximately at one panel's value. Parallel raises current while voltage stays approximately at one string's value. Mismatched panels and uneven shading require additional analysis that this tool does not perform.
Why the cold-condition factor matters
Panel Voc is normally specified at reference test conditions. Voltage varies with temperature, and cold conditions can raise open-circuit voltage. Use the exact panel temperature coefficient, the coldest design condition, and the method required by the applicable manuals or qualified system designer. The default 1.10 factor is an editable example, not a universal rule.
How to interpret a stop result
- Cold Voc above maximum: do not connect that series count.
- Vmp outside the operating range: the controller may not start, track, or operate as intended; obtain exact manufacturer guidance.
- Isc or Imp above the entered current limit: do not connect that parallel count.
- Nameplate above station watts: the station may clip input, but overpaneling is not automatically permitted. The manual must explicitly support the complete voltage/current/power configuration.
Continue the purchase decision
Compare eight current portable panels →Estimate recharge hours and solar days →Primary references
- U.S. Department of Energy: series raises voltage and parallel raises current
- NREL: PV module and array current-voltage characteristics
- U.S. Department of Energy: voltage, current, temperature, and PV performance
- EcoFlow: model-specific series/parallel recommendations and station limits
- Power Prep Labs methodology and safety boundaries