A sump pump is not a steady load.
The difficult number is usually motor startup. The uncertain number is runtime, because the pump's duty cycle changes with water inflow.
Three requirements
- Continuous output: the station must sustain the pump while running.
- Starting capability: it must tolerate the motor's brief inrush without shutting down.
- Energy: capacity must cover how often and how long the pump cycles during the outage.
Measure a wet-weather cycle
Record the pump's watts, seconds per cycle, and cycles per hour during representative inflow. Average watts are approximately running watts multiplied by the fraction of each hour the pump runs. Use a conservative wet-weather scenario, not a dry-day observation.
Redundancy matters
A portable station can support the primary pump, but it does not address every failure mode. Consider an independently powered secondary pump, water-powered backup where appropriate, alarms, and a documented response plan. Never place electrical equipment where it can be exposed to flooding.
Connection safety
Do not backfeed house wiring through an outlet. Hardwired loads, transfer equipment, and panel integration require properly rated equipment and qualified installation. Verify grounding, neutral, GFCI behavior, cable ratings, and the station manufacturer's instructions.
Use the calculators
First decide whether you need only outage power or a separate pumping path with the power-station vs dedicated-backup guide. Then use the startup-surge guide to keep amps, VA, and watts distinct and the 6-, 12-, and 24-hour capacity table to see why wet-weather duty cycle dominates runtime. The calculator turns a measured cycle into an energy estimate and model screen; open the full multi-load calculator when other equipment will share the station.