Independent outage planning

Keep what matters
running.

Build your essential-load plan. We’ll estimate the battery capacity, continuous output, and startup surge your backup power needs—without pretending every outage looks the same.

TransparentEvery assumption is visible
EditableUse your actual nameplate watts
IndependentNo pay-to-rank placements
01 / SIZE YOUR SYSTEM

What needs to stay on?

Start with a preset or add your own device. Replace representative values with the wattage from your equipment label or a power meter whenever possible.

Quick add
PLANNING ASSUMPTIONS

Leave a little room for reality.

MULTIDAY STRESS TEST

Can this plan repeat after day one?

Enter one exact station and a realistic daily recharge window. We’ll compare the repeated load schedule above with the energy available across a longer outage.

Starting usable energy—Wh at the AC load
Usable recharge per day—Wh after stated losses
Total outage demand—Wh across repeated plans
Energy-budget resultBuild the load plan firstTiming, weather, fuel, input limits, and surge still require separate checks.

This repeats the device schedule above once per day. Recharge input must be the power the station actually accepts—not a panel or generator headline. The result is an energy budget, not proof that charging and load timing will work. Never operate a fuel-burning generator indoors or in a garage.

* For CPAP or other medical equipment, use this only for general energy planning. Follow the device manufacturer’s approved backup-power guidance and maintain an appropriate emergency plan.

VERIFIED MODEL DATABASE

Stations that clear this plan

0 of 27 current models meet both the calculated battery-capacity and continuous-output minimums. Surge compatibility is shown separately when the manufacturer publishes a rating.

Affiliate disclosure: Power Prep Labs may earn a commission from clearly labeled shopping links, at no extra cost to you. Paid relationships never change the calculator thresholds or model order. No paid links are currently active.

ModelCapacityAC outputSurge checkWeightSourceShop
Loading verified model data…

A model appearing here is not a recommendation or guarantee. The matcher does not yet evaluate voltage, waveform, ports, grounding, transfer equipment, environmental limits, or every manufacturer restriction.

Compare any three current models against the same load →
02 / NO BLACK-BOX MATH

See where every watt goes.

Our estimate separates power, energy, and motor startup—three numbers that product roundups often blur together.

1

Average the load

Running watts × quantity × duty cycle gives each device’s average demand.

Σ watts × qty × duty
2

Count the hours

Average demand × required hours gives raw energy before conversion losses.

average watts × hours
3

Allow for losses

Efficiency and reserve turn ideal energy into a practical minimum battery capacity.

raw Wh ÷ efficiency ÷ usable %
4

Check the surge

Motors can briefly draw far more than their running watts. The station must clear continuous and startup tests.

running load + largest startup increment
Read the full methodology and limitations →
03 / BUY FOR THE JOB

Start with the outage—not the brand.

Browse calculation-first guides by protected load, measurement task, exact model, or supporting outage accessory.

Cutaway view of a refrigerator and kitchen lights powered by a portable battery during a nighttime outage
FOUNDATION GUIDE

Refrigerator & freezer backup

Plan for cycling loads, compressor surge, food safety, and realistic outage duration.

Read the field guide →
Rainy-night house cutaway showing a basement sump pump supplied by a portable battery
HIGH-SURGE LOAD

Sump pump backup

Why horsepower, water inflow, and startup current change the answer.

Read the field guide →
Winter house cutaway showing warm living space and basement heating equipment supported by backup power
WINTER HEATING BACKUP HUB

Start with the kind of heating system

Choose the correct path for a gas furnace, hydronic boiler, pellet stove, heat pump, or electric resistance heat.

Choose the winter backup path →
QUIET BACKUP

Apartment outages

Silent, indoor-safe backup plans for renters with limited storage.

Read the field guide →
MEDICAL-DEVICE PLANNING

CPAP backup power

Estimate overnight energy while preserving the manufacturer’s safety boundaries.

Read the field guide →
HOME-INTERNET CONTINUITY

Keep Wi-Fi on during an outage

Trace and measure the modem, ONT, router, switches, mesh nodes, and essential work device before choosing a UPS or larger battery.

Build the minimum online stack →
PRELOADED OUTAGE PLAN

Fridge + Wi-Fi + lights

Work through a transparent 24-hour essentials example, then replace every input.

Open the outage plan →
WORK + FOOD CONTINUITY

Home office + refrigerator

Size a 24-hour food plan alongside a focused 10-hour workday, then edit every assumption.

Open the outage plan →
HIGH-CAPACITY COMPARISON

3–5 kWh home-backup class

Compare six expandable, high-output systems without confusing base capacity, total output, or surge claims.

Compare verified models →
OUR EDITORIAL PROMISE

Useful before profitable.